50~600A (LA37S family)
Suitable for middle power of general purpose inverter
Product Features
- ASIC model / High-speed response
- Compact Design
- Wide measuring range ; 150 ~ 1200A
- Panel mounting, Connector on secondary ( 2 types )
LA37SxxxS05M、LA37SxxxS05KM : MOLEX/22-04-1041, Sn-plated terminal connecter
(Gold-plated terminal connecter of product can be build to order)
LA37SxxxS05J、LA37SxxxS05KJ : JST/B4B-XH-A-G Gold-plated terminal connecter - Aperture’s size:□20.3×10.3mm
Main Applications
Linear Open Loop current sensors with 4 series and 2 derivations for a total of 28 models.
- Primary nominal current ; 50~600 A
- Power supply specifications ; +5V
- With reference access(Vref_in/out)
- Two types of rated output voltage; Vof ± 800mV or Vof ±625mV
- Two types of connectors according to the application
- Non ratiometric output (Vout, Voff, Vref)
Series | Symbol | LA37SxxxS05 | LA37SxxxS05K | (Conventional model) L37SxxxS05x |
---|---|---|---|---|
Power supply voltage | Vcc | +5V | +5V | +5V |
Primary nominal current | I PN | 50~600A | 50~600A | 50~600A |
Primary current, measuring range (Saturation current) | I PM | 150~1200A | 150~1200A | 150~900A |
Internal reference voltage | Vref | +2.5V | +2.5V | +2.5V |
Offset voltage | Vof | +2.5V or Vref_in | +2.5V or Vref_in | +2.5V or Vref_in |
Rated output voltage (at I PN) | Vo | Vof±800mV | Vof±625mV | Vof±625mV |
Ambient operating temperature | T A | -40~+105℃ | -40~+105℃ | -40~+85℃ |
Temperature drift of reference voltage | TcVref | ±10mV (T A=full range) | ±10mV (T A=full range) | ±190ppm/K |
Temperature drift of offset voltage | TcVof | ±10mV (T A=full range) | ±10mV (T A=full range) | ±1mV/K |
Temperature coefficient of sensitivity | TCG | ±3% (T A=full range) | ±3% (T A=full range) | ±0.24%/K |
Spec sheet | - |
LA37S family
General characteristics
- Open loop, Voltage-output type, ASIC model
- Powe supply voltage :+5V,
Rated output voltage(LA37SxxxS05x):Vof ±800mV / (LA37SxxxS05Kx):Vof ±625mV
Offert voltage(Vof):2.5V or Vref-IN
Non ratiometric output (Vout, Voff, Vref) - Insulation voltage:AC3.3kV, 50Hz, 1min
- Ambient Operating temperature : -40 ~ +105℃
- Creepage distance :5.5mm.min
Standard compliance
- UL 508 (UR marking)
- Using UL94-V0 recognized materials
- European Directive : CE marking(EN62477-1)
Spec sheet
Contact & Download Materials
Suitable products are proposed to meet your specific needs. Feel free to contact us for more information.
Search for Products
Search by Keywords