50~150A (F26P family)
Suitable for power conditioner, High stability (Low temperature drift) Primary through type, Fluxgate system
Product Features
- Closed Loop Fluxgate system used
- Super precision at +85℃ and -40℃.
- With reference access (Ref_In/Ref_Out). (S12 is reference voltage output function available)
- 3 standard models F26PxxxS05x, Primary nominal current(Maximum current) ; 50A(150A), 100A(270A), 150A(230A)
F26P150S12:Primary nominal current : 150 A ( Measuring range : 450 A ) - F26PxxxS05A; Output voltage waveform distortion improvement model
- Through hole type (Aperture size : 20.5×11.0 mm), PCB mounting type
Main Applications
Flux-gate Series Current Sensors with 3 series and 2 derivations for a total of 7 models.
- Primary nominal current ; 50~150 A
- Power supply specifications ; +5V or +12 V
- With reference access (Ref_in / Ref_out), * F26P150S12 has only Vref (OUT) function
- PCB mounting design
- Model number suffix A; Output voltage waveform distortion improvement model
Series | Symbol | F26PxxxS05 | F26PxxxS05A | F26PxxxS12 |
---|---|---|---|---|
Power supply voltage | Vcc | +5V | +12V | |
Primary nominal current | I PN | 50~150A | 150A | |
Primary current, measuring range (Saturation current) | I PM | 150~230A | 450A | |
Output voltage (at I PN) | Vo | +2.5V or Vref_in ±0.625V | +2.5V ±0.625V | |
Offset voltage | Vof | +2.5V or Vref_in | +2.5V | |
Ambient operating temperature | Ta | -40 ~ +85℃ | ||
Structure | Dimensions and pin assignments are the same | |||
Aperture's size : □20.5×11 mm | ||||
Remarks | Base model | Output voltage waveform distortion improvement model | Wide type of measuring range Vref(OUT) only | |
Spec sheet |
F26P family
General characteristics
- Closed Loop Fluxgate system used, Voltage-output type
- Unipolar power supply : +5V, Rated output voltage : Vof +0.625V, Offset voltage : +2.5V or Vref_in (S05、S05A)
Unipolar power supply : +12 V, Offset voltage ( Vof ): +2.5 V, Rated output voltage : Vof +0.625 V (S12) - Insulation voltage : 4.3kV AC, 50 Hz, 1 min.
- Ambient Operating temperature : -40 ~ +85℃
- Creepage distance and Clearance distance : 12.7 mm
Standard compliance
- UL 508 (UR marking)
- Using UL94-V0 recognized materials
- European Directive : CE marking
Spec sheet
Contact & Download Materials
Suitable products are proposed to meet your specific needs. Feel free to contact us for more information.
Search for Products
Search by Keywords