S27S300D15Y

caraS27S300D15Y

Appearance
S27S300D15Y
Suitable for middle power of UPS and general purpose inverter

yaji1Features

Multi-mount : possibility to vertically or horizontally
Maximum current : 500A (RL ≦ 22Ω), Primary norminal current : 300A
Panel mounting, Connector on secondary ( 2 types )
yaji1S27S300D15Y : MOLEX/39-28-8040, Sn-plated terminal connecter
yaji1S27S300D15YM : MOLEX/38-00-6293, Sn-plated terminal connecter
Aperture’s size : φ20

yaji1General characteristics

Closed loop, Current-output, Turn ratio 1: 2000
Bipolar power supply : ±15V, Rated output current : 150mA(@300A)
Secondary coil resistance : 25Ω(@Ta=70℃)
Insulation voltage : AC4.0kV, 50Hz, 1min

yaji1Standard compliance:

UL 508 (UR marking)
Using UL94-V0 recognized materials
European Directive : CE marking

yaji1Spec sheet

icon_1r_24Spec sheet